Projekt

Allgemein

Profil

Wiki » Historie » Version 24

Maximilian Seesslen, 01.10.2024 13:14

1 1 Maximilian Seesslen
h1. Wiki
2
3
There are some issues that can only be tested via power resets.
4
5
* SPI has an issue that it needs retries
6
* Looks like configuration I2C EEPROM gets reset to defaults
7 3 Maximilian Seesslen
* RTC-offline-test (Wie lange haelt die RTC Batterie)
8 1 Maximilian Seesslen
9 3 Maximilian Seesslen
The device has an CANBus in and an CANBus out. The testsoftware is on the DUT. The DUT sends the command to toggle power line to Awaria via CAN.
10
The switch-off time has to be an parameter. The RTC-Tests will be complex, the Awaria software shall be simple and generic.
11 2 Maximilian Seesslen
12
An data multiplexer can be used along with a mosfet for power line.
13 13 Maximilian Seesslen
Data lines for CAN and UART have to be cut. 
14
In order to cut UART, an Debug-Adapter chaining would be needed. Or Uart is available via Host-USB.
15 2 Maximilian Seesslen
16 15 Maximilian Seesslen
Optionally controll it via USB from PC, not MCU. Optically isolated GPIOs.
17 12 Maximilian Seesslen
18 14 Maximilian Seesslen
h1. Problem
19
20
Circuit does not help at all when power is injected into device via Pullup of RS232. Lines can be disabled too. But whole
21 1 Maximilian Seesslen
debug connector can cause issues: No debug connection at all.
22 15 Maximilian Seesslen
FPC with UART only? All signals disconnectable?
23 14 Maximilian Seesslen
24 24 Maximilian Seesslen
h1. Usecases
25
26
* Devices have their own test-software and ask awaria to perform an power-cycle for them. Result is stored in option Bytes.
27
* PC performs test. DUT has to send Log-Events when errors show up and when device is up and running. DUT firmware can be the productive firmware.
28
** Tester-Firmware on PC is quite generic
29
** CAN may not be available yet (CANDis). That was one intention of repeated log code
30
** CANDis may be configured to use USB. No UART output here. USB does also not help then.
31
32 2 Maximilian Seesslen
h1. Parts
33
34
* MCU: The smallest thing
35 1 Maximilian Seesslen
* Multiplexer:
36 3 Maximilian Seesslen
** MC14551BDG bis zu 1K RON: 1050
37
** TS5A23166DCUR cool, 2 channels, up to 100mA, 1,8-6,5V
38 6 Maximilian Seesslen
** Habe:
39 7 Maximilian Seesslen
*** DG408LEDQ-T1-GE3; .#273;  1:8
40 20 Maximilian Seesslen
*** DG409LEDQ-T1-GE3; .#321;  2x 1:4
41 8 Maximilian Seesslen
*** ADG736; .#315; 2x1:2
42 20 Maximilian Seesslen
*** *RS2102XN ADG836YRMZ* Das ist er; 2x
43 21 Maximilian Seesslen
** MAX4760; 8 Channels; Paarweise schalten
44
** TMUX1574 4xSPDT; 1 Schalter
45
** PI5C3257QE; 4xSPDT; 1 Schalter; 0.229€
46 6 Maximilian Seesslen
47 5 Maximilian Seesslen
* Big EEPROM, device can store test info from DUT
48 4 Maximilian Seesslen
49
Spannungs/Strom zu umstaendlich.
50 10 Maximilian Seesslen
51
h1. RTC-Tests
52
53
Can have a region in SPI-Flash.
54 11 Maximilian Seesslen
If the Settings are not ok, just have an terminal.
55
The test can only be started from terminal.
56
rebootTest <startTime>
57
58 10 Maximilian Seesslen
Start. 
59
* Cut 2 Seconds. Time OK?
60
* Cut 4 Seconds. Time OK?
61 1 Maximilian Seesslen
* Cut 8 Seconds. Time OK?
62 11 Maximilian Seesslen
63
When it fails, "destroy" test-config in spi flash
64 12 Maximilian Seesslen
65
h1. Connectors
66
67
* CANBus-In
68
* CANBus.Out
69
* Power in
70
* Power out
71 17 Maximilian Seesslen
* -USB PC to MCU-
72
* -USB PC to DUT-
73
74
Debug, CAN, power only?
75
CAN-Geraete koennten auch standalone laufen, Testsoftware auf PC.
76 18 Maximilian Seesslen
77
78
2x Uart
79
2x SWD
80
1x Reset
81 19 Maximilian Seesslen
1x Boot0
82
2x CAN
83 22 Maximilian Seesslen
(DEBUG: VDD_5VIN, GND, VDD_TGT, SWO)
84 23 Maximilian Seesslen
85
USB schalten is overkill, andere Platine.